Minimum height above the roof surface 1 flat to 7 12.
Minimum clearance on water heater roof vent.
Type b vents ceiling floor wall clearances b vent clearances to combustibles clearance distances for a b vent to combustible materials in floors walls ceilings attics roofs.
Gas appliance direct vent clearances distances from direct gas vent to building features sidewall vent direct vent direct exhaust systems for gas fired heaters water heaters other appliances.
Single wall vents should have a minimum of 6 inches of clearance and double wall sometimes called a b vent should have 1 inch minimum clearance.
They exhaust moist air to the outside.
If the water heater is installed above the door or window it needs 12 inches of clearance.
Whenever we are installing a gas water heater building codes require that there should be a ventilator out of the room through the attic and out through the roof.
Aluminum 012 inner wall galvanized 018 outer wall.
2 5 feet above the roof surface.
1 0 foot above the roof surface 1 7 12 to 8 12.
Number 3 is a vent for an attic space called a roof vent or turtle vent.
Distance required canada 1.
84 2 1m 3 note 5.
Hot water is an essential part of everyday life.
Single wall vent pipes cannot pass through a ceiling floor firewall or wall.
This article series describes b vent metal chimneys used for gas fired appliances.
Direct vent gas fireplace exhaust termination item clearance distance.
1 5 feet above the roof surface.
Many people can t live without a water heater.
We discuss fire safety fire clearances and other gas appliance venting details for b vent chimneys.
Distance required usa 2.
Metal vents that are too close to wood or combustionable materials may cause the wood to burst into flames.
An exception is made for non combustible walls such as solid masonry or concrete.
Stack vents may give off sewer gas so they should not be located within 3 feet of an operable window.
Materials and construction round type b gas vent 3 8 and oval 4 6.
Natural gas fireplaces gas fired furnaces boilers water heaters and wall or space heating applications.
Table of rooftop chimney clearances for metal b vent chimneys flues.
For gas fired water heater vents.
Number 2 is a vent for an exhaust fan like those found in bathrooms and laundry rooms.
Clearance above paved sidewalk or a paved driveway located on public property.
A direct vent installation only requires a 12 inch setback from the door or window.
6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
Minimum clearance distance requirements for the exterior vent termination of a gas fireplace heater 8.
2 0 feet above the roof surface.